top of page
ádfghjk.png
Frame 33.png

Advanced sensors and electronics for real-time building intelligence and performance monitoring.

Where we monitor

Learn our different investigative monitoring solutions

Wall monitoring
Vector 2 (1).png
Vector 3.png
Historic Masonry Wall Monitoring

RESEARCH INSTALLATION

Example of an installation SMT may do on a test building lab

PNG image 5.png

Parameters Measured

  • Interior air conditions

  • Moisture level in plaster, interior brick, brick (inner & outer) and sandstone (inner, outer & upper)

  • Condensation level in cavity air space

  • Differential pressure between interior & exterior air gap

  • External crack-movement tracking

RESEARCH INSTALLATION

(With Driving Rain Gauge)​

PNG image 4.png

COMMERCIAL INSTALLATION

Installation that SMT may perform on a commercial project

PNG image 2.png
Wood Wall Monitoring

COMMERCIAL INSTALLATION

7088df_fe06d70845ac45a59c035e30ecf37e24~mv2.jpeg

Parameters Measured

  • Interior air conditions

    Moisture level in: plaster, interior brick, brick (inner and outer), sandstone (inner, outer and upper)     

  • Condensation level in: cavity air space

  • Differential pressure: interior and exterior air gap

  • External crack movement tracking

RESEARCH INSTALLATION

Parameters Measured

  • Interior air conditions

    Moisture level in: plaster, interior brick, brick (inner and outer), sandstone (inner, outer and upper)     

  • Condensation level in: cavity air space

  • Differential pressure: interior and exterior air gap

  • External crack movement tracking

7088df_c573d61e2ed8457b92046eccc62753e9~mv2.jpeg
Roof monitoring
Vector 2 (1).png
Vector 3.png
For Conventional Roof Systems

Using Moisture Detection Tape (MDS), Point Moisture Monitoring (PMM), and Relative Humidity Sensors to analyze trends, weather, moisture, and temperature profiles.   

PNG image.png
For Inverted Roof Systems

Using DigiStars and Electrical Field Tape (EFT), FutureCast is able to track long-term moisture trends in inverted roof systems.

SMT Research LinkedIn.png
Foundation monitoring
Vector 2 (1).png
Vector 3.png
7088df_6218e7293dfe46fbb94dd760f7d42b91~mv2.jpeg
Moisture Detection Tape (MDS)
  • Can be put along the crack or inserted into the crack

  • Cut to length

  • Records when and how much moisture is detected when water bridges the stainless steel hardware.

  • Discrete and flexible

  • Can easily be put in different locations for a when/how wet measurement.

Point Moisture Monitoring Sensor (PMM)
  • Two screws that can be screwed into the concrete crack.

  • Used if you are looking for presence of water and when/how wet the concrete is.

  • Measures the resistance between the two screws

  • More localized moisture measurement versus the MDS Tape.

7088df_41549d23c4864c3083b015e1c6c342cb~mv2.jpeg
7088df_43b16a51faaf41d7af0e46a00f13b6d0~mv2.jpeg
Embedded Moisture Sensor (EMS)
  • Installed by drilling and inserting into the concrete, then filled with dry grout

  • Gets the moisture level of the concrete surrounding it - not just water on the surface.

  • When two EMS sensors are installed at different depths in a slab, you will be able to see the different moisture levels in each.

  • Can show which way the water is travelling and which surface the water is drying to.

7088df_e014a813dbe94ab98cec91bb32a51448~mv2.jpeg
Concrete Moisture Sensor (CMS)
  • Once calibrated the sensor can give very accurate moisture level and moisture content readings in concrete.

  • Measures the capacitance and dielectric change of moisture in the concrete.

  • Can be “cut” in the slab, or poured in place.

Window monitoring
Vector 2 (1).png
Vector 3.png
Window Leak Detection Monitoring
80b50b_f2e352cb7ea944dd95a197ef2d422029~mv2.jpeg

Parameters Measured

  • Parameters Measured​

  • Window Leak Detection

  • Wall Moisture

  • Interior air conditions

  • Moisture content of exterior wall sheathing

  • Condensation potential in wall cavity air space 

  • Perfect for window retrofit projects or new construction

Window Condensation Monitoring
80b50b_4a2ff4e2eec44be183cedd5adc4cc66a~mv2.jpeg

Parameters Measured

  • Window Leak Detection

  • Wall Moisture

  • Interior air conditions

  • Moisture content of exterior wall sheathing

  • Condensation potential in wall cavity air space 

  • Perfect for window retrofit projects or new construction

Advanced Window System Performance
80b50b_fafa6fa106554982910ef1c597f5ef2c~mv2.jpeg

Parameters Measured

  • Window glazing performance 

  • Comparison of reflective coating and glazing properties

  • Condensation monitoring 

  • Interior air conditions

    • Relative Humidity

    • Temperature Dew point 

  • Exterior air conditions 

    • Relative Humidity 

    • Temperature Dew point 

  • Interior of glazing and frame temperature 

  • Exterior of glazing and frame temperature 

  • Optional openable window status 

    • % open/close 

  • Optional occupant use study 

    • status of lights

    • heating system

    • blind open/close

  • Perfect for window system evaluation prior to retrofit or new construction 